Search results for "Lateral pressure"
showing 5 items of 5 documents
Experimental investigation on the compressive behavior of short-term preloaded carbon fiber reinforced polymer-confined concrete columns
2017
Strengthening of concrete columns with fiber reinforced polymer sheets provides a good improvement to the existing structural members in terms of load and strain capacity due to the properties of the composite jacket. A proper knowledge of the load–strain response of the composite members is necessary to design retrofitting intervention of existing structures; however, so far the available design methods do not allow to take into account the effect of the possible presence of service loads on the compressive behavior of the reinforced columns. An experimental investigation on the compressive behavior of preloaded circular concrete columns reinforced with carbon fiber reinforced polymer was …
Compressive response of substandard steel-jacketed RC columns strengthened under sustained service loads: From the local to the global behavior
2018
Abstract This paper presents an experimental investigation on substandard partially steel jacketed RC columns strengthened under sustained loads and loaded until failure. The aim of the study is to compare the compressive response of preloaded columns with respect to the tests without preload to obtain a more realistic prediction of load-carrying capacity of structural columns after retrofitting under serviceability loads. The influence of the preload level, the delayed contribution of the confining device during the loading process and the time dependent effects are highlighted for the tested specimens. Based on the experimental observations, an analysis-oriented model is proposed for the …
A strategy for the finite element modeling of FRP-confined concrete columns subjected to preload
2018
Abstract Compressive behavior of columns strengthened by means of an outer elastic confinement provided e.g. by fiber-reinforced polymer (FRP) jackets has become a main topic in the field of structural retrofitting. In details, the problem of the response assessment of strengthened columns is still under study. Many analytical formulations have been proposed to describe the compressive behavior of confined concrete under both monotonic and cyclic loads. However, the effect of a stress/strain level in the columns already present prior to apply the confinement has been generally neglected until now, also because of the lack of well defined strategies of modeling. In this frame, here, (1) a FE…
Efficiency of Stress-Strain Models of Confined Concrete With and Without Steel Jacketing to Reproduce Experimental Results
2016
The improvement and the capacity assessment of existing buildings has become the main topic of the last years so that different studies can be found devoted to damaged structures or structures not having a capacity compatible with the safety levels of the actual codes. Reinforced concrete framed structure buildings represent a conspicuous rate of the existing constructions so many efforts are addressed to them. Referring to this type of buildings, a good prediction of strength and deformation capacity requests models able to interpret the constitutive law of concrete confined by internal reinforcement or by eventual external reinforcement applied to increase capacity of cross-sections. Cons…
Transmembrane helix–helix interactions are modulated by the sequence context and by lipid bilayer properties
2012
Abstract Folding of polytopic transmembrane proteins involves interactions of individual transmembrane helices, and multiple TM helix–helix interactions need to be controlled and aligned to result in the final TM protein structure. While defined interaction motifs, such as the GxxxG motif, might be critically involved in transmembrane helix–helix interactions, the sequence context as well as lipid bilayer properties significantly modulate the strength of a sequence specific transmembrane helix–helix interaction. Structures of 11 transmembrane helix dimers have been described today, and the influence of the sequence context as well as of the detergent and lipid environment on a sequence spec…